+91-84089 03000

      Standard Sales Corporation

We are Authorised Channel Distributor, Dealer, Supplier, Trader, Exporter of Schneider Electric ACB (Air Circuit Breakers), EasyPact MVS, Draw-out type Circuit breakers and Switch Disconnectors 800-4000A, Draw Out ACB, Draw-out type circuit with microprocessor based ET2L teip unit, Fixed type circuit breaker with microprocessor based ET6G trip unit, Accessories from Pune, Maharashtra, India.


Draw-out type Circuit breakers and Switch Disconnectors 800-4000A

Draw-out type Circuit breakers and Switch Disconnectors 800-4000A

  • Conforms to IS/ IEC 60947-2 & 3
  • Microprocessor based ET trip systems with thermal memory
  • No derating up to 500C
  • Zone Selective Interlockings
  • Fully rated neutral with inbuilt protections
  • Pre trip alarm & individual fault indicating LEDs
  • ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
  • Icu=Ics=Icw(1sec) = 50kA @ 440V AC


EasyPact MVS Draw Out ACB

Draw the type circuit breaker with microprocessor based ET6G unit (without display)

Rating
In (A)
3P Draw-Out Manual
Reference
3P Draw-Out
Electrical Reference
4P Draw-Out
Manual Reference
4P Draw-Out
Electrical Reference
800 MVS08N3MW6L MVS08N3NW6L MVS08N4MW6L MVS08N4NW6L
1000 MVS10N3MW6L MVS10N3NW6L MVS10N4MW6L MVS10N4NW6L
1250 MVS12N3MW6L MVS12N3NW6L MVS12N4MW6L MVS12N4NW6L
1600 MVS16N3MW6L MVS16N3NW6L MVS16N4MW6L MVS16N4NW6L
2000 MVS20N3MW6L MVS20N3NW6L MVS20N4MW6L MVS20N4NW6L
2500 MVS25N3MW6L MVS25N3NW6L MVS25N4MW6L MVS25N4NW6L
3200 MVS32N3MW6L MVS32N3NW6L MVS32N4MW6L MVS32N4NW6L
4000 MVS40N3MW6L MVS40N3NW6L MVS40N4MW6L MVS40N4NW6L


EasyPact MVS draw out ACB

ACB variants LP changes for product
Configuration w.r.t. ACB having
ET6G trip unit.
How to arrive at new reference number*
Switch Disconnector version
(without trip unit)
Reduce    19300 Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
switch disconnector reference replace 6L by 0D i.e MVS08N3MW0D
ACB with ET6A trip unit
(LCD display with Current Metering)
Add    9200 Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
ACB reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MW6A
ACB with ET6V trip unit
(LCD display with Current Metering &
Voltage Metering and Last 10 Trip History)
Add    21200 Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
ACB reference with ET6V trip unit replace 6L by 6V i.e MVS08N3MW6V


Draw-out type circuit with microprocessor based ET2L teip unit (without display)

  • Conforms to IS/ IEC 60947-2 & 3
  • Microprocessor based ET trip systems with thermal memory
  • No derating up to 50˚C
  • Fully rated neutral with inbuilt protection
  • Pre trip alarm & individual fault indicating LEDs
  • ET2L provides Overload & Short-circuit protections
  • Icu=Ics=Icw(1sec) = 50kA @ 440V AC

Rating
In (A)
3P
Draw-Out Manual
Reference
3P Draw-Out
Electrical
Reference
4P Draw-Out
Manual
Reference
4P Draw-Out
Electrical
Reference
800 MVS08N3MW2L MVS08N3NW2L MVS08N4MW2L MVS08N4NW2L
1000 MVS10N3MW2L MVS10N3NW2L MVS10N4MW2L MVS10N4NW2L
1250 MVS12N3MW2L MVS12N3NW2L MVS12N4MW2L MVS12N4NW2L
1600 MVS16N3MW2L MVS16N3NW2L MVS16N4MW2L MVS16N4NW2L
2000 MVS20N3MW2L MVS20N3NW2L MVS20N4MW2L MVS20N4NW2L
2500 MVS25N3MW2L MVS25N3NW2L MVS25N4MW2L MVS25N4NW2L
3200 MVS32N3MW2L MVS32N3NW2L MVS32N4MW2L MVS32N4NW2L
4000 MVS40N3MW2L MVS40N3NW2L MVS40N4MW2L MVS40N4NW2L

EasyPact MVS Draw out ACB

ACB variants LP changes for product
configuration w.r.t. ACB having
ET2L trip unit
How to arrive at new reference number
ACB with ET2A trip unit (LCD display
with Current Metering)
Add      4600 Example : ACB reference with ET2L trip unit - MVS08N3MF2L.
For ACB reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MF2A
ACB with ET2V trip unit (LCD display
with Current Metering & Voltage
Metering and Last 10 Trip History)
Add     13800 Example : ACB reference with ET2L trip unit - MVS08N3MF2L.
For ACB reference with ET2V trip unit replace 2L by 2V i.e MVS08N3MF2V


Fixed type circuit breaker with microprocessor based ET6G trip unit (without display)

  • Conforms to IS/ IEC 60947-2 & 3
  • Microprocessor based ET trip systems with thermal memory
  • No derating up to 50˚ C
  • Zone Selective Interlocking
  • Fully rated neutral with inbuilt protection
  • Pre trip alarm & individual fault indicating LEDs
  • Icu=Ics=Icw(1sec) =50kA @ 440V AC

Rating
in (A)
3P Fix Manual
Reference
3P Fix Electrical
Reference
4P Fix Manual
Reference
4P Fix Electrical
Reference
800 MVS08N3MF6L MVS08N3NF6 MVS08N4MF6L MVS08N4NF6L
1000 MVS10N3MF6L MVS10N3NF6L MVS10N4MF6L MVS10N4NF6L
1250 MVS12N3MF6L MVS12N3NF6L MVS12N4MF6L MVS12N4NF6L
1600 MVS16N3MF6L MVS16N3NF6L MVS16N4MF6L MVS16N4NF6L
2000 MVS20N3MF6L MVS20N3NF6L MVS20N4MF6L MVS20N4NF6L
2500 MVS25N3MF6L MVS25N3NF6L MVS25N4MF6L MVS25N4NF6L
3200 MVS25N3MF6L MVS32N3NF6L MVS32N4MF6L MVS32N4NF6L
4000 MVS40N3MF6L MVS40N3NF6L MVS40N4MF6L MVS40N4NF6L


EasyPact MVS Draw out ACB

ACB variants LP changes for product
Configuration w.r.t. ACB having
ET6G trip unit.
How to arrive at new reference number*
Switch Disconnector version (without trip unit) Reduce  19300 Example : ACB reference with ET6G trip unit - MVS08N3MF6L.
For switch disconnector reference replace 6L by 0D i.e MVS08N3MF0D
ACB with ET6A trip unit (LCD display with Current Metering Add   9200 Example : ACB reference with ET6G trip unit - MVS08N3MF6L.
For ACB reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MF6A
ACB with ET6V trip unit (LCD display with Current Metering &
Voltage Metering and Last 10 Trip History)
Add   21200 Example : ACB reference with ET6G trip unit - MVS08N3MF6L.
For ACB reference with ET6V trip unit replace 6L by 6V i.e MVS08N3MF6V


Fixed type circuit breaker with microprocessor based ET2L trip unit (without disply)

  • Conforms to IS/ IEC 60947-2 & 3
  • Microprocessor based ET trip systems with thermal memory
  • No derating up to 50° C
  • Fully rated neutral with inbuilt protection
  • Pre trip alarm & individual fault indicating LEDs
  • Icu=Ics=Icw(1sec) =50kA @ 440V AC

Rating in
(A)
3P Fix Manual
Reference
3P Fix Electrical
Reference
4P Fix Manual
Reference
4P Fix Electrical
Reference
800 MVS08N3MF2L MVS08N3NF2L MVS40N3NF2L MVS08N4NF2L
1000 MVS10N3MF2L MVS10N3NF2L MVS10N4MF2L MVS10N4NF2L
1250 MVS12N3MF2L MVS12N3NF2L MVS12N4MF2L MVS12N4NF2L
1600 MVS12N3MF2L MVS16N3NF2L MVS16N4MF2L MVS16N4NF2L
2000 MVS20N3MF2L MVS20N3NF2L MVS20N4MF2L MVS20N4NF2L
2500 MVS25N3MF2L MVS25N3NF2L MVS25N4MF2L MVS25N4NF2L
3200 MVS32N3MF2L MVS32N3NF2L MVS32N4MF2L MVS32N4NF2L
4000 MVS40N3MF2L MVS40N3NF2L MVS40N4MF2L MVS40N4NF2L





EasyPact MVS (Accessories)

Component Specification Reference
Gear Motor (MCH)    
AC 50/60 Hz 100/130 V 47893
200/240 V 47894
380/415 V 47896
24/30 V 47888
DC 48/60 V 47889
100/125 V 47890
200/250 V 47891
Closing Release (XF)    
24/30 V DC 33659
48/60 V DC 33660
AC 50/60 Hz DC 100/130 V AC/DC MVS15511
200/250 V AC/DC MVS15512
380/480 V AC MVS15513
Opening Release (MX)    
24/30 V DC, 24 V AC 33659
48/60 V DC, 48 V AC 33660
AC 50/60 Hz DC 100/130 V AC/DC 33661
200/250 V AC/DC 33662
380/480 V AC 33664
Terminal Block    
For drawout circuit breaker   47849
Under Voltage Release (MN)    
AC 50/60 Hz DC 24/30 V DC, 24 V AC 33668
48/60 V DC, 48 V AC 33669
100/130 V AC/DC 33670
200/250 V AC/DC 33671
380/480 V AC 33673
MN Delay Unit    
AC 50/60 Hz DC 48/60 V AC/DC 33680
100/130 V AC/DC 33681
200/250 V AC/DC 33682
380/480 V AC/DC 33683
100/130 V AC/DC 33684
200/250 V AC/DC 33685
ON/OFF Indication Contacts (Additional OF contact)    
1 additional block of 4 contacts   47887
Door Interlock (VPECD)/1 part    
On right hand side of chassis   47914
Operation Counter    
Operation Counter CDM   48535

Request A Quote